HYDAC FAM 75E Oil Purifier

Product Enquiry

Description

HYDAC Vacuum Dehydrators

HYDAC FAM 75E Oil Purifier

The FluidAqua Mobil FAM Economy / HYDAC FAM 75E Oil Purifier series operates on the principle of vacuum dewatering to eliminate free and dissolved water as well as free and dissolved gases from hydraulic and lubrication fluids. Since it uses HYDAC offline filter element technology with its high contamination retention capacity and filtration efficiency, the unit is extremely economical. All units are equipped with an AquaSensor AS 1000 for continuous monitoring of the water content and control of the unit.

An FCU 1000 (see Accessories) can be connected for temporary measurement of particle contamination. To increase the dewatering capacity, for high viscosity fluids or for low fluid temperatures, an integrated heater is provided. The Siemens S7 series of programmable logic control (PLC) in combination with a Siemens control panel guarantees simple and reliable operation in many languages.

Benefits of the HYDAC FAM 75E Oil Purifier
Extremely low residual water levels, gas levels and particle contamination in the operating fluids make for:

  • Longer oil change intervals
  • Improved component service life
  • Greater machine availability
  • Reduction in the LifeCycle Cost (LCC)

 

HYDAC FAM 75E Oil Purifier

FAM
75E
Flow rates IN at 50(60) Hz
Max. ≈ 90(103) l/min
Flow rates OUT at 50(60) Hz
Max. ≈ 90(103) l/min
Permitted fluids**
Mineral oils to DIN 51524
Gear oils to DIN 51517, 51524 Synthetic esters (HEES) DIN 51524/2
Vegetable oils (HETG, HTG)
HFD-R fluids (not for pure phosphate ester for which EPDM seals are required).
Sealing material
FKM (FPM, Viton®)
Filter size of fine filter
OLF-100
Filter elements for fine filter
N100DMxxx
… 150 mm2/sec
≥ 2 μm
… 460 mm2/sec
≥ 10 μm
… 1100 mm2/sec
≥ 20 μm
Clogging indicator
VM 2 C.0
Pump type, vacuum pump
Rotary vane vacuum pump
Operating pressure (outlet)**
≈ 1.5 … 4.5 bar
Permitted pressure at suction port (without suction hose) **
-0.2 … +1 bar
Operating viscosity range**
15 … 800 mm²/sec without built-in heater
15 … 1100 mm2/s with integrated heater
Fluid temperature range **
10 … 80°C
Ambient temperature **
10 … 45°C
Storage temperature range **
10 … 45°C

 

Electrical power consumption* without built-in heater
≈ 8.3 kW
Electrical power consumption* with built-in heater
≈ 26.3 kW
Heating output (optional)
≈ 18 kW
Protection class
10 m / CEE (depending on the nominal voltage, see model code)
Length of hoses
5 m (mobile FAMs only)
Material of hoses
see model code
Connection inlet/outlet
see Connection summary table
Weight when empty
≈ 465 kg
Achievable residual water content
100 ppm – hydraulic and heavy oils
50 ppm – turbine oils (ISO VG 32/46)
10 ppm – transformer oils ***

* Maximum specifications given, equipment-dependent
** For other fluids, viscosities or temperature ranges, please contact us.
*** Units not suitable for “Online” and “Onload” operation (transformer in operation and connected to grid).